Emergency Exit Terminal

for Interlock Control Systems

Kenmerken

The DICTATOR interlock control system provides a terminal designed especially for doors in emergency exits. These doors are equipped both with the normal control terminal and an additional emergency exit terminal.

This terminal only serves for unlocking the door in an emergency. Normally the interlock door is operated by the control terminal (without emergency-open switch).

The emergency exit terminal has been tested by the German TÜV Thüringen and is approved for its use on emergency exit doors (German standard for electrical locking systems on emergency exits EltVTR), certificate no. P-3250/08. For an easy mounting boxes for flush and surface mounting are available.

Productinformatie

Technical Data

Power consumption24 VDC, approx. 80 mA
IP ratingIP 20
Operating temperature-10 °C to +40 °C
Emergency-open contact set (capacity)2 NC contacts: 2,8 A
Input signal from hazard alert systemNC contact
Output to signal (horn etc.)24 VDC, max. 1,4 A

Functioning

The emergency-open switch of the emergency exit terminal permits to unlock the door of the interlock system in case of an emergency. The used locking device has to be an approved one (see DICTATOR bar magnets here or electric strikes here). The power supply of the connected bar magnet is interrupted and the door unlocked.
The emergency exit terminal is provided with contacts for an external signal (siren, lamp, horn), even supplying a power of up to max. 1.4 A for the signal. (ATTENTION: this power consumption has to be taken into account when calculating the required performance of the power pack).
The emergency-open command can also be given directly by a facility management centre. This, however, requires that the system is configured for the global emergency-open.

The door status is indicated by the two lamps on the terminal:

Red LED on: Door is locked electrically.
Green LED on: Door is released.

KontaktschlossSwitching Device

After an emergency unlocking the door has to be locked again by a separate switching device within splitting distance of the door like for instance the loose-key switch with stainless steel front plate (AISI 304), part no. 710960 (see tab Dimensions).
The half profile cylinder (according to DIN 18252) has to be provided by the customer.

Dimensions

All dimensions in mm

Emergency exit terminal

Part no. 710833

Fluchtwegterminal Maße

Loose-key switch

for relocking the door after an emergency-opening.
Without profile cylinder!
Part no. 710960 (switching capacity max. 4 A, 30 VDC)

Fluchtwegterminal Kontaktschloss Maße

Bestelinformatie

OmschrijvingArtikelnr.
Sealable cover shed for emergency open button710839
Surface box P for the emergency exit terminal of the interlock control system, powder coated white, RAL 9010710835
Flush box P for the emergency exit terminal of the interlock control system, model for metal profiles710834
Surface box P for the control/operating terminal, powder coated white-aluminium, RAL 9006710832
Surface box P for the control/operating terminal, powder coated white, RAL 9010710831
Flush box P for the control/operating terminal of the interlock control system, model for metal profiles710829